2/14/2024 0 Comments 4 copper wire![]() *Data provided on this page is subject to change based on different manufacturers variances. Nylon Jacket Thickness: 0.150 mm / 0.006 inchesĪllowable Ampacity: 70 Amps at 60✬ / 85 Amps at 75✬ / 95 Amps at 90✬ PVC Insulation Thickness (Conductor): 1.020 mm / 0.040 inches Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8Ĭolor-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-8 4 AWG THHN/THWN-2 Specifications*: Solid, uncoated copper conductors per ASTM-B3 Institute of Electrical and Electronics Engineers All sizes are rated gasoline and oil-resistant II.Ī tough, polyamide, Nylon outer covering per UL-1063 and UL-83. We offer free shipping on all orders over 1000. ![]() Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105☌ in dry locations.Ĥ AWG Copper wire, 4 AWG THWN-2, 4 AWG Building Wire, hook up wire, conduit wire, lighting wire, nylon copper wire, construction cable, 4 Gauge Wire, etc. Our 4 AWG THHN/THWN-2 copper building wire can be cut to your desired length and purchased by the foot. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90☌, or not to exceed 60☌ in wet locations or where exposed to oils or coolants. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90☌ or not to exceed 75☌ in oil or coolants. 4 AWG THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Choose from our selection of 4 gauge wire in a wide range of styles and sizes. Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Power servomotors, servocontrollers, and servodrives in automated equipment and assembly lines. Enter the desired footage in the QTY box. Copper Tube Joints Working Pressure Solder or Brazing Joints Based on ASME Standard B31.Cut to length - sold by the foot.Chemical Finish Black Oxide for Copper, Mil-F-495.Smaller bare conductor diameters than those shown.Īmerican Wire Gauge (AWG) Wire Size Chart Conductors with compact and compressed stranding have about 9 percent and 3 percent, respectively, These items are shipped from and sold by different sellers. Sigma Electric ProConnex 41309 Ground Clamp 1/2 to 1-Inch, 1-Pack, 1 Count (Pack of 1), Bar. Using conductors having coated strands, different stranding type, and, especially, other temperatures changes the resistance.ģ. This item: 4 AWG Solid Bare Copper Wire (100ft cut) 19874. These resistance values are valid only for the parameters as given. Staff of Research and Education Associationġ. Reference: Handbook of Scientific and Engineering Data Cross-sectional area for busbars is typically rated in terms of circular mils (even for square and rectangular bars!), most likely for the convenience of being able to directly equate busbar size with round wire. Although a square or rectangular cross-section is very common for busbar shape, other shapes are used as well. Busbars are usually made of copper or aluminum, and are most often uninsulated. In these instances, thick bars of solid metal called busbars are used as conductors. Stranded wire construction is favored, instead.įor some high-current applications, conductor sizes beyond the practical size limit of round wire are required. This is a handy rule to remember when making rough wire size estimations!įor very large wire sizes (fatter than 4/0), the wire gauge system is typically abandoned for cross-sectional area measurement in thousands of circular mils (MCM), borrowing the old Roman numeral "M" to denote a multiple of "thousand" in front of "CM" for "circular mils." The following table of wire sizes does not show any sizes bigger than 4/0 gauge, because solid copper wire becomes impractical to handle at those sizes. Specifications : Size AWG : 4/0, Weight per 1000 ft : 710 lbs, Outside Diameter : 0.660 inches, Conductors : Annealed Soft Copper per ASTM B3 and ASTM B8. The American Wire Gauge (AWG) measurement system was designed with a purpose: for every three steps in the gauge scale, wire area (and weight per unit length) approximately doubles. Instrumentation, Electrical, Control and Sensing DevicesĪWG Copper Wire Table Size and Data Chart 100 Degrees F AWG Copper Wire Size and Data Table Chart 100 Degrees F
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |